Simultaneous display of “Current Value” and “Baseline Value,” allowing for direct baseline setting
This compact unit features a dual-screen display. Current and baseline values can be viewed simultaneously, allowing for smooth verification and setting of baseline values without switching between display modes.

Clearer, Better Visibility
White LED displays offer enhanced visibility and a wider field of view than conventional green LED displays.

Equipped with two independent outputs and three output modes
Equipped with two independent comparative outputs, it can confirm vacuum break in adsorption applications and output a total pressure alarm when confirming total pressure. Three output modes are available.

Close-fitting mounting
A dedicated panel mount and bracket are available to support close-fitting mounting.



Applicable Gases: Air, non-corrosive, non-flammable gases
Display: Three-color display (red, green, and orange)
Rated pressure range: -100 to +100 MPa
Set pressure range: -101 to +101 MPa
Maximum withstand pressure: 500 MPa
Comparative output (NPN output type)
Maximum sink current: 100 mA
Applied voltage: 30 V DC or less
Residual voltage: 2 V DC or less (at 100 mA sink current)
Power supply voltage: 12 to 24 V DC ±5%
Current consumption: Normal: 720 mW or less; STD mode: 480 mW or less; FULL mode: 360 mW or less
Display accuracy: Within ±2 digits
Repeatability: Within ±0.1% F.S.; Within ±2 digits
Temperature characteristics: Within ±0.5% F.S. (at +20°C)
Operating temperature: -10 to 50°C
Storage temperature: -10~+60°C (non-icing, non-condensing)
Temperature Range: 35~85% HR
Ingress Protection: IP40
Connection: Plug-in
Material: Back Cover: ABS, off-white; Housing: PC, off-white