Equipped with dual circuits
Equipped with two switching safety outputs and a safety self-check function, the product is safer to use.
Anti-interference line synchronization
The light barrier features a line synchronization detection method. Line synchronization requires a green synchronization line connection, which enhances the light barrier’s anti-interference capabilities.
Multiple detection types
Three types are available, depending on the minimum detectable object size.

Impact-resistant, thick-walled, and durable housing
The H3EL features a sturdy metal housing, reliably protecting it from impacts such as collisions with workpieces and being stepped on.


Light Source: Infrared LED (peak emission wavelength: 850nm, modulated)
Number of Optical Channels
8-88 lamps, in increments of 2
Optical Channel Spacing: 10mm
Protective Height: 70mm-870mm (Protective Height H = (N-1) * 10mm, where N is the number of optical channels)
Protective Distance: 0.1-2.5m
Minimum Detection Object: Opaque objects φ15mm or larger (completely shielded from light)
Output Mode: 1. NPN Transistor Open Collector Output (Normal Closed)
Maximum Sink Current: 200mA; Applied Voltage: 30V DC or less (between NPN output and 0V)
Residual Voltage: 2V or less (at 200mA sink current); 1.2V or less (at 100mA sink current)
- PNP Transistor Open Collector Output (Normal Closed)
Maximum Source Current: 200mA; Applied Voltage: 30V Residual voltage below DC (between output and +V): 2V or less (sourcing 200mA); 1.2V or less (sinking 100mA)
Synchronization type: Linear
Response time: T = (N + 1) * 1.2 (where N is the number of optical axes). Example: H3EL1610-NC: Response time: T = (16 + 1) * 1.2 = 20.4ms
Operating voltage: DC 12-24V ±10% fluctuation, (p-p) 10% or less
Current consumption: <50mA
Power consumption: <1.5W
Residual voltage: Residual voltage <2V when load current <200mA
Load current: <200mA
Protection circuit: Surge protection, overcurrent, short-circuit protection, and reverse polarity protection
Operating temperature: -10°C to 55°C (non-condensing)
Operating humidity: Relative humidity <85% at 20°C
Ambient illumination Incandescent lamp: <3000 Lux (incident angle |>20°); Sunlight: <10000 Lux (incident angle |>50°); LED light: <30000 Lux.
Vibration resistance: 10-55 Hz, 1.5 mm amplitude, X/Y/Z axes, 2 hours each.
Ingress protection: IP60.
Material: Housing: 6063 aluminum alloy, high-gloss yellow finish; End caps: PC; Window: PMMA, 940 nm translucent brown.