High Resolution
High-precision measurement with a resolution of 0.5µm makes it suitable for a wide range of applications in various production sites.

Easy Operation
You can set the distance by observing the distance indicator. There are seven LED indicators, indicating distances from near to far, and you can operate them directly with the buttons on the control panel.

Four Detection Ranges
A variety of models are available with detection ranges of 30 ± 5mm, 50 ± 10mm, 85 ± 20mm, and 250 ± 150mm.

Equipped with multiple usage types
Equipped with four usage types, you can choose to meet your needs based on different usage locations.

Cable Outlet
Equipped with a two-meter flex-resistant cable.



Sensing distance: 30mm ±5mm
Light source: 655nm red laser
Output modes: NPN/PNP/analog voltage (0-10V)/analog current (4-20mA)
Repeatability: 0.5μm
Linearity: ±0.05%
Spot size: 0.3mm
Ambient temperature: Operating: 0-45°C, Storage: -15-+60°C (no icing or condensation)
Ambient humidity: Operating and storage: 35-85% RH each
Power supply: 12-24V DC ±10%, ripple: 10% P-P maximum
Current consumption: Maximum 100mA
Protection circuit: Overload and reverse polarity protection
Temperature drift: ±0.1% F.S./°C
Vibration resistance: 10-55Hz, double amplitude 1.5mm
Ambient illumination: Incandescent lamp: 3000lux maximum
Casing material: PBT + fiberglass
Ingress protection IP65
Connection method: Lead wire (standard lead wire length 2m)